At Grade
Step 1:Excavate the intake trench from the edge of the liner to the Filter Tank. If the Filter Tank is level with the water feature, dig the intake trench so the pipe will be level.

Below Grade
Step 1:When the top of the Filter Tank is placed lower than the rim of the vanishing pool, the rim of the pool becomes your reference point. To find the penetration point of the intake pipe, measure down 8-3/4” for 4” and 6” pipe and 10-3/4” for 10” pipe. Elbow down accordingly to connect to the Filter Tank intake port.

Step 2: Place the Flex-Coupling
over the intake port and tighten the stainless steel clamp.


Step 3: Insert the intake pipe into the coupling and tighten the stainless steel clamp.

 

 

Step 1: Using the cardboard tracing pattern, draw a circle on the liner at the center point of the pipe.

Note: Allow an expansion fold below the pipe.


Step 2: With scissors, cut out the traced circle from the liner.
Step 3: Stretch the liner over the pipe; this creates a tight sleeve band around the pipe.

 

Step 4: Place the flex-collar over the rubber band and tighten.
Step 5: Connect the Flex-Coupling to the pipe.

 

Step 6: Insert the skimmer outlet to the Flex-Coupling.

 

Step 7: Check to ensure all stainless steel clamps have been tightened. Then firmly backfill over the intake pipe so that it will stay level when it comes time to fill the system with water.

 


< Back to berkeysupply.com